某塔装置工程脚手架搭设施工方案(英汉互译).doc
《某塔装置工程脚手架搭设施工方案(英汉互译).doc》由会员分享,可在线阅读,更多相关《某塔装置工程脚手架搭设施工方案(英汉互译).doc(11页珍藏版)》请在第壹文秘上搜索。
1、 目 录Content1工程概况General12 施工依据References13施工程序Construction Procedures14施工技术要求Construction Technical Requirements25脚手架计算书Scaffolding Calculation76 HSE措施HSE Measures 91 工程概况 General 此方案用于-装置C4450、C3170、C3140、R4420、V2704、V3090、V3091、V3100、V3120、V3130、V3172脚手架搭设,脚手架用来进行平台爬梯安装工作。This method statement is
2、prepared for the scaffolding erection for the platform & ladder installation of C4450、C3170、C3140、R4420、V2704、V3090、V3091、V3100、V3120、V3130、V3172 in.2 编制依据 References:1) 扣件式钢管脚手架搭设要求与设计计算JGJ 130-2001Erection Requirements and Design Calculation for the Steel Tubular Scaffold with Fastener JGJ 130-200
3、12) 石油化工企业施工安全技术规程SH3505-1999Safety Technical Regulations for Petrochemical Construction SH3505-19993 施工程序 Construction Procedures施工准备材料准备机具就位N人员体检、培训Y接受架设委托 架 设N检查验收、挂合格牌Y交 付 使 用架 设 拆 除Construction PreparationTools & Equipments in PlaceNMaterial PreparationPhysical Examination & TrainingY Accept Er
4、ection EntrustingErectionInspection & Acceptance; Put on Qualification TagNYHand overScaffolding Dismantling4 施工技术要求 Construction Technical Requirements 4.1 地面处理 Ground Preparation 1) 架设前放置立杆底座板,立杆插放在底座板上,增大立杆的受力面积,增强架设的稳定性。Before erection, put the jack base under the rickers to increase the force a
5、rea of rickers and strengthen the erection stability. 2) 架设用材料选用须符合下列要求:The scaffolding materials should comply with the following requirements: a) 架杆选用48mm,壁厚3.5mm的钢制管道,材质符合GB7008-79对Q-235A钢的要求。Use the steel tubes 48mm with 3.5mm thick wall as the scaffold poles. The materials should be in accordan
6、ce with the requirements to steel Q-235A by GB7008-79. b) 扣件选用型号为KT-33-8的可锻铸铁,扣件紧固用螺栓选用材质为Q-235A钢制作。Use the mollealle iron KT-33-8 to be the fasteners. Bolts to fix fasteners should be fabricated by steel Q-235A.c) 跳板选用材质为Q-235A钢制作,厚度不低于2mm。Use steel Q-235A to fabricate the planks, with thickness 2m
7、m or more.4.2 脚手架搭设型式及设备平台安装顺序Scaffolding Erection Type and Installation Sequence of Platform of Equipments1) 采用双排扣件式井字脚手架。The scaffolding shall be double-row “#”-shape scaffolding with fasteners.2) 设备平台、附塔管线安装顺序:脚手架搭设到每层平台处后(离设备平台约1.2米),安装设备平台及与下层设备连接直梯;设备平台安装完毕后,继续往上搭设脚手架,安装设备平台和爬梯。(见附图1)。 Install