adidas Group Color Manual-2006.docx
-
资源ID:705040
资源大小:158.54KB
全文页数:23页
- 资源格式: DOCX
下载积分:5金币
友情提示
2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。
|
adidas Group Color Manual-2006.docx
DearSupplier,Wearepleasedtoannouncethere-launchingofthenewadidasGroupColorManual.Thismanualhasbeenrevisedtotakeintoconsiderationbothrecentadvancesincolortechnologyandfuturedevelopmentsincolormanagementthatweforeseeinthenexttwotofiveyears.ThismanualcontainsCOlOrSPeCifiCatiOnSforallfabricsandgarmentsthataresuppliedtotheadidasGroup.ThesestandardsandprocesseshavebeendevelopedtoensurethatadidasGroupmerchandiserepresentsourcommitmenttohighqualityforourcustomerswhilstatthesametime,furtherimprovingourproductdevelopmentleadtimes.UponacceptinganorderfromadidasGroupyouareacknowledgingtomeetthecolorspecificationsasstatedinthismanual.Shouldyouhaveanyquestionsregardingthecontentsofthismanualypleasecontactthefollowing:IrisBakker-adidasGroup-HQHerzogenaurach+49-9132-845987iris.bakkeradidas.deChristineCollins-adidasGroup-Portland+1-971-234-4265christine.collinsadidasusAcknowledgementofReceiptfor2006adidasGroupColorManualPleasesignbelowandreturnthispagetotheadidasGroupofficeinyourregionBysigningyouareacknowledgingreceipt&compliancetothismanualSupplierName:(Pleaseprint)RecipientsName:(Pleaseprint)Signature:DateofReceipt:ASia-PaCifiCDeanLiou-AdidasSourcingLtd-MPCTaipei5/F99sec.2Jen-aiRoadTaipei,Taiwan10062R.O.C.Email:dean.liou(三)adidas.hkPhone:+886-2-23574285NorthandSoUthAmeriCaPaulaTurgeon-adidasInternational5055NorthGreeleyAvenuePortland,OR97217USAEmail:paula.turgeonadidasusPhone:+971-234-4265EUroPeDeryaCetin-adidasSourcingLtd-MPCIstanbulEskiBuyukdereCad.ParkPlazaNo.2234398MaslakzIstanbul-TurkeyEmail:derya.cetinadidas.trPhone:+90-212-3295533TableofContentsPageSeetiOnIntroductionII.T2&TiInstrument,Software&Accreditation5-6RequirementsIII.ColorStandards7-IV.EvaluationofColorAssessors9V.LightingCabinet10-11VI.InstrumentalColorMeasurementProcedures:12-14SpectrophotometerA. SpectrophotometerSettingsB. SpectrophotometerCalibrationC. SpectrophotometerMeasurementTechniqueVII.ApprovalViewingProcedureA. NumericalTolerancesB. PhysicalSampleViewingRequirements15-16VIII.Metamerism17IX.ImportantNotetotheSupplyBase18X.adidasGroupGlobalCoIorTooIsForms19-21XI.ColorContinuity22XII.BasicCoIorTheory23-32I. INTRODUcnONWezatadidasGroupvaluemaintainingahighlevelofqualityinourproductsandonlybyensuringthatourprocessesareaccuratelycommunicated,ourmethodsdocumentedandourspecificationsdefined,thisgoalwillbemet.Itisourobjectivetoclearlycommunicateourexpectationsandparameterstooursupplybase.Wewill,onacontinuousbase,evaluateandadoptourprocessesinordertoimproveproductquality.Wevalueourrelationshipswithoursupplybaseandrealizethatbyworkingtogetherwecanaccomplishourmutualgoalofprovidingqualityproductsandservicestoourcustomers.Aswebetterdefineourexpectations,weseektoestablishforoursuppliersaworkingrelationshipwhereperformanceisrewardedandtrustisestablished.ItistheadidasGroupPolicytocommunicatecolorandspecifycolorstandardsusingthe31pointspectraldatameasurementsystemandtocontrolcolorusingtheCMC2:1colorequationtogetherwiththeguidelinesandprocedurescontainedherein.Theinstrumentalspectraldatameasurementprocessworksonnumericaldataandtolerances,resultinginmoreefficientandobjectivecolordecisionsascomparedtovisualassessmentalone.adidasGroupofficesareequippedwithhighqualityDatacolorSF600+CTandSF600XSpectrophotometersandDatacolorTools,Envision&Tracksoftwareforcolormeasurement,evaluation,trackingandcommunication.Allcolorstandardsandsupplierssubmitsaremeasuredandstoredelectronicallyandsupplierperformancereportsaregeneratedtoprovideavarietyofdataincludingqualityoffirstsubmissions;approvalpercentagesandturntimes.ThemaingoaloftheadidasGroupColorManualincludesignificantlydecreasingthenumbersofcolorsubmissionsreceivedfromthesupplybasepriortoapprovalandreducingthetimeandcostassociatedwiththecolorprocess.Tosupportthisgoalwerequiresupplieraccreditationtohelpensureongoingaccuracyandconsistencyofcolorsubmissions.II. T2&TIINSTRUMENT,SOFTWARE&ACCREDrrATloNREQUIREMENTSTier2Suppliers(DyeMills)mustbeequippedwithbelowinstruments&softwareandmustensurethefollowingrequirements: ADatacolorSF600+CTorSF600XorDatacolor600Spectrophotometer.TheonlyotherspectrophotometermodelsacceptabletoadidasGroup(forsuppliersalreadyeuiDDedwithalternativehardware)aretheGretagMacbethCE7000A&C0l0ri7andtheMinolta3700D. DatacolorColortoolsQCsoftwareVersion3.12orhigher,orDatacoIorTooIsQCsoftwareVersion1.0orhigher DatacolorTracksoftware Anofficiallyapprovedlightingcabinet(seepage10)locatedinadarkroomorinacurtainedoffarea CabinetsneedtobefittedwithD65ArtificialDaylight,TL84GeneralStoreLight(Fn)andUVUltraviolet 1.ighttubesmustbereplacedevery2zooohoursor6months,whicheverissooner InteriorsurfaceofthelightingcabinetmustbepaintedinaneutralgreycolorEmulsionGrey5574oralternativelyEmulsionGreyN5 Anannualcalibration,maintenanceandcertificationofrequiredinstrumentsfromthemanufacturerorofficiallyapprovedservicepartnerisma